IRA-3T
(Output Range 0-100 psig)
|
|
-
Diaphragm design for increased low pressure
sensitivity
- Provides a regulated sample supply to
chromatographs, H2S analyzers,
gravitometers. calorimeters,
moisture
analyzers, and other on line
analyzing
equipment
- Inhibits carry over of free liquids into
instrument supply system
- Patented Automatic insertion Device allows
insertion and removal of probe
from a high
pressure pipeline through a
full open isolation
valve without pipeline shutdown
(specify
insertion length)
- 1" NPT connection standard, larger
sizes
available
- Flanged connection available up to 900
ANSI in RF, RTJ, etc.
- Thermal fins on probe offset temperature
change at point of regulation
- 316 stainless steel construction
- 1,800 psig maximum inlet pressure (higher
pressures available Upon request)
- Teflon seat (Kel-F scat optional)
- 1/4" NPT ports standard, other sizes
available
- Cv .092
(Downstream relief required) |
IRA-4SS (Output Range 0-100 psig)
|
|
-
Diaphragm design for increased low
pressure sensitivity
- Provides a regulated sample supply to
chromatography H2S
analyzers,
gravitometers, calorimeters,
moisture
analyzers, and other on line
analyzing
equipment
- Inhibits carry over of free liquids into
instrument supply system
- Patented Automatic insertion Device allows
insertion and removal of probe
from a high
pressure pipeline through a
full open
isolation valve without pipeline
shutdown
(specify insertion length)
- 1" NPT connection standard, larger
sizes
available
- Flanged connection available up to 900
ANSI in RF, RTJ. etc.
- Thermal fins on probe offset temperature
change at point of regulation
- 316 stainless steel construction
- 1,800 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- CV .138
(Downstream relief required) |
|
IRA-3TP (Output Range
100-2001)
|
|
- Piston design for higher output pressures
- Provides a regulated sample supply to
chromatography H2S
analyzers,
gravitometers, calorimeters,
moisture
analyzers, and other on line
analyzing
equipment
- Inhibits carry over of free liquids into
instrument supply system
- Patented Automatic insertion Device allows
insertion and removal of probe
from a high
pressure pipeline through a
full open
isolation valve without pipeline
shutdown
(specify insertion length)
- 1" NPT connection standard, larger
sizes
available
- Flanged connection available up to 900
ANSI in RF, RTJ, etc.
- Thermal fins on probe offset temperature
change at point of regulation
- 316 stainless steel construction
- 1,800 psig maximum inlet pressure (higher
pressures available upon request)
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- CV .092
(Downstream relief required) |
RELIEF VALVES
RV-1
|
|
-
For moderate capacity applications
- 0-200 psig range
- Male 1/4" NPT inlet. other sizes
available
- Optional female 1/2" NPT outlet,
model RV-1D
- 316 stainless steel construction
- CV .890 |
RV-2
|
|
-
For high pressure, low capacity applications
- 0-2,000 psig range
- Male 1/4" NPT inlet, other sizes
available
- Optional male 1/4"NPT outlet, model
RV-2S
- 316 stainless steel construction
- CV .038 |
RV-3D
|
|
-
For low pressure, high capacity applications
- 0-50 psig range
- 316 stainless steel construction
- 1" NPT outlet
- CV 1.18 |
CHECKVALVES
CV-1
|
|
-
1/4" NPT inlet male and female
- 316 stainless steel construction
- Check valves are available in any
combination of port sizes and
types |
|