IR-4
(Output Range 0-100 psig)
|
|
-
Diaphragm design for increased low
pressure sensitivity
- Range springs for 0-25 psig. 0-50 psig,
or 20
100 psig
- Available in high strength aluminum (7075-
T6), or 316 stainless steel
- 3.000 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- Cv .138
(Downstream relief required) |
IR-1T (Output Range 0-100 psig)
|
|
-
Diaphragm design for increased
low pressure sensitivity
- Range springs for 0-25 psig, 0-50
psig, or 20-100 psig
- 316 stainless steel construction
- 5,000 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other
sizes available
- Cv .092
(Downstream relief required) |
IR-lTP (Output Range 20-200 psig)
|
|
- Piston design for higher output pressures
- 316 stainless steel construction
- 5,000 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- Cv .092
(Downstream relief required)
|
IR-2KP (Output Range 100-500 psig)
|
|
- Piston design for higher output pressures
- 316 stainless steel construction
- 5,000 psig maximum inlet pressure
- Kel-F seat
- 1/4" NPT ports standard. other sizes
available
- Cv .092
(Downstream relief required)
|
|
IR-6KP (Outout Range 250-2,000
psig)
|
|
- Special piston design for higher output
pressures
- 316 stainless steel construction
- 5,000 psig maximum inlet pressure
- Kel-F seat
- 1/4 NPT ports standard, other sizes available
- Cv .092
(Downstream relief required)
|
IRD-4SS (Output Range 0-100 psig)
|
|
- Diaphragm design for increased low
pressure sensitivity
- Provides a regulated sample supply to
chromatography H2S
analyzers,
gravitometers, calorimeters,
moisture
analyzers, and other on line
analyzing
equipment
- Inhibits carry over of free liquids into
instrument supply system
- Inlet probe extends 3 1/2" into pipeline
(other
lengths available)
- 1/2", 3/4", and 1" NPT
connection standard,
larger sizes available
- Flanged connection available up to 1440
ANSI in RF, RTJ. etc.
- Thermal fins on probe offset temperature
change at point of regulation
- 316 stainless steel construction
- 3,000 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- CV .138
(Downstream relief required)
|
IRD- 1 TP (Output Range 100-200
psig)
|
|
- Piston design for higher output pressures
- Provides a regulated sample supply to
chromatography H2S
analyzers,
gravitometers, calorimeters.
moisture
analyzers. and other on line
analyzing
equipment
- Inhibits carry over of free liquids into
instrument Supply system
- Inlet probe extends 3 1/2" into pipeline
(other
lengths available)
- 1/2", 3/4", and 1" NPT
connection standard,
larger sizes available
- Flanged connection available Up to 1500
ANSI in RF. RTJ, etc
.- Thermal fins on probe offset temperature
change at point of regulation
- 316 stainless steel construction
- 5,000 psig maximum inlet pressure
- Teflon seat (Kel-F seat optional)
- 1/4" NPT ports standard, other sizes
available
- CV .092
(Downstream relief required) |
|