The purpose of this sampler is to provide a safe
and efficient method for sampling refined product.
This sampling process requires larger volumes per
sample than other sampling procedures, necessitating
the larger size pumps.

Principle of Operation
A double acting power cylinder is connected to a smaller
sampling cylinder pump. As the piston retracts via
actuation by the sample signal, product is pulled
into the small cylinder. The reverse actuation causes
the valve actuator to switch the 3-way valve to allow
product to be pumped from the cylinder into the sample
container.
|