CP-42GA Constant Pressure Sample Cylinder
Technical Data
(Standard)

Application
The CP-42GA can be used with all products that are compatible with the materials of construction and seal material.

Pressure Rating
Standard working pressure is 1800 psi (124 Bar).

Temperature Rating
From -20 to +250 °F (-29 to +121 °C).

Sample Container Sizes
4000cc standard.

Materials
Standard material used is 7075-T6 aluminum with Viton and Fluorotrel seals.

 

Connections
Product and precharge ports are 1/4" FNPT.

Required Utilities
A nitrogen bottle can be utilized for precharge gas blanket. Other gases typically used are helium and argon.
CAUTION: Neveruse liquids for precharge pressure.

Weight (4000cc)
7lbs.
3.2 kg.

Non-standard designs available upon request
Options Available

- Other volumes
- Other materials of construction
- Gravity mixer
- 1/2" FNPT porting
- Resettable spring reliefs
- Certificates (material 3.1 b, hydrostatic,functional,
   conformity, etc.)